131I-Human Serum Albumin

DiagnosticsTheranostics

131I-Human Serum Albumin

Description

131I-Human Serum Albumin (131I-HSA) is a radiopharmaceutical agent utilized in medical diagnostics, primarily for human fluid analysis and imaging applications. It plays a crucial role in determining total blood and plasma volumes for blood analysis and is also employed in the localization of cerebral neoplasms during imaging procedures.

Clinical Applications

The clinical utility of 131I-HSA spans across a range of diagnostic purposes:

  1. Blood and Plasma Volume Analysis:
    • Essential for assessing total blood and plasma volumes.
    • Useful in evaluating cardiac output and measuring cardiac and pulmonary blood volumes.
    • Facilitates the determination of circulation times, offering insights into systemic and pulmonary circulation.
  2. Imaging and Tracing:
    • Aids in delineating the heart and great vessels for diagnostic clarity.
    • Used in protein turnover studies and localization of specific anatomical structures such as the placenta and cerebral neoplasms.
  3. Therapeutic Value:
    • The data obtained from blood analysis are instrumental in refining diuretic prescriptions.
    • Provides critical information for the diagnosis and management of hypertension, septic shock, and blood loss during surgery.

Availability

131I-HSA is available from select manufacturers, tailored to distinct applications:

  • Imaging:
    • Iso-Tex Diagnostics (Megatope™, US MA 1976)
    • FUJIFILM (131I-HSA Injection)
  • Blood Analysis:
    • Daxor Corporation (Volumex)

Pricing and Dosage:
For blood analysis, the typical patient dose costs approximately EUR 200 (USD 260), with an administered dose of about 25 µCi. Imaging applications generally require higher doses.

Competitive Landscape

The market for 131I-HSA is relatively niche with limited competition. While 131I is the preferred isotope, it can be substituted with alternatives such as 125I or 123I in certain scenarios.

  • Specialized Equipment:
    Daxor Corporation has developed a proprietary device specifically designed for determining blood and plasma volumes using 131I-labeled compounds.
  • Alternative Imaging Tracers:
    Various other tracers not reliant on 131I are available for imaging, which may provide options for broader clinical applications.

Comments

131I-HSA addresses highly specific medical indications, particularly in blood analysis and imaging. However, the imaging segment faces competition from alternative tracers that do not utilize 131I, offering clinicians a range of diagnostic options. Despite this, its precise applications and diagnostic accuracy make 131I-HSA a valuable tool in specialized medical scenarios.

You must be logged in to comment.
Please log in to leave a comment.